{"product_id":"vacufil-complete-vacuum-filtration-unit","title":"Vacufil : Complete Vacuum Filtration Unit","description":"\u003cp data-start=\"90\" data-end=\"416\"\u003eVacufil is a complete \u003cstrong data-start=\"112\" data-end=\"138\"\u003evacuum filtration unit\u003c\/strong\u003e designed for \u003cstrong data-start=\"152\" data-end=\"249\"\u003eefficient, high-speed, and contamination-free filtration of biological and chemical solutions\u003c\/strong\u003e. Built with advanced membrane technology, this system is ideal for laboratories requiring \u003cstrong data-start=\"340\" data-end=\"415\"\u003ereliable filtration of proteinaceous solutions, culture media, and sera\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"418\" data-end=\"644\"\u003eVacufil units are widely used in international markets such as the USA, UK, Germany, and Europe due to their \u003cstrong data-start=\"527\" data-end=\"603\"\u003elow protein binding, high flow rate, and superior filtration performance\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-section-id=\"1xufjnw\" data-start=\"651\" data-end=\"694\"\u003e\u003cstrong\u003eWhat is Vacufil Vacuum Filtration Unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"696\" data-end=\"931\"\u003eVacufil is a \u003cstrong data-start=\"709\" data-end=\"760\"\u003eready-to-use, complete vacuum filtration system\u003c\/strong\u003e that includes a filtration funnel, membrane, and receiver bottle. It is specially designed to handle \u003cstrong data-start=\"862\" data-end=\"930\"\u003esensitive biological samples without affecting their composition\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"933\" data-end=\"1110\"\u003eThe unit typically features a \u003cstrong data-start=\"963\" data-end=\"1012\"\u003e75mm diameter Polyethersulfone (PES) membrane\u003c\/strong\u003e, ensuring efficient filtration with minimal protein loss. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-section-id=\"1e05ouj\" data-start=\"1117\" data-end=\"1143\"\u003e\u003cstrong\u003eWhere Is Vacufil Used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1145\" data-end=\"1191\"\u003eVacufil filtration units are commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"1193\" data-end=\"1560\"\u003e\n\u003cli data-section-id=\"5q9hmr\" data-start=\"1193\" data-end=\"1274\"\u003e\n\u003cstrong data-start=\"1195\" data-end=\"1230\"\u003eBiopharmaceutical Laboratories:\u003c\/strong\u003e Filtration of serum and protein solutions\u003c\/li\u003e\n\u003cli data-section-id=\"clyikk\" data-start=\"1275\" data-end=\"1337\"\u003e\n\u003cstrong data-start=\"1277\" data-end=\"1299\"\u003eMicrobiology Labs:\u003c\/strong\u003e Sterile filtration of culture media\u003c\/li\u003e\n\u003cli data-section-id=\"23d31h\" data-start=\"1338\" data-end=\"1405\"\u003e\n\u003cstrong data-start=\"1340\" data-end=\"1367\"\u003eResearch \u0026amp; Development:\u003c\/strong\u003e Sample preparation and purification\u003c\/li\u003e\n\u003cli data-section-id=\"1hbc9nm\" data-start=\"1406\" data-end=\"1479\"\u003e\n\u003cstrong data-start=\"1408\" data-end=\"1435\"\u003eBiotechnology Industry:\u003c\/strong\u003e Processing of sensitive biological fluids\u003c\/li\u003e\n\u003cli data-section-id=\"8bhobm\" data-start=\"1480\" data-end=\"1560\"\u003e\n\u003cstrong data-start=\"1482\" data-end=\"1508\"\u003eChemical Laboratories:\u003c\/strong\u003e Filtration of aqueous and mild chemical solutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1562\" data-end=\"1645\"\u003eThey are ideal for applications where \u003cstrong data-start=\"1600\" data-end=\"1644\"\u003esample integrity and purity are critical\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-section-id=\"3qqqcg\" data-start=\"1652\" data-end=\"1675\"\u003e\u003cstrong\u003eWhy Choose Vacufil?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1677\" data-end=\"1783\"\u003eVacufil is designed for \u003cstrong data-start=\"1701\" data-end=\"1742\"\u003ehigh efficiency and sample protection\u003c\/strong\u003e, especially for protein-based solutions.\u003c\/p\u003e\n\u003cp data-start=\"1785\" data-end=\"1808\"\u003eKey advantages include:\u003c\/p\u003e\n\u003cul data-start=\"1810\" data-end=\"2019\"\u003e\n\u003cli data-section-id=\"1s601mm\" data-start=\"1810\" data-end=\"1848\"\u003eLow protein binding membrane (PES)\u003c\/li\u003e\n\u003cli data-section-id=\"zalc4i\" data-start=\"1849\" data-end=\"1889\"\u003eHigh flow rate for faster filtration\u003c\/li\u003e\n\u003cli data-section-id=\"1tjdq1j\" data-start=\"1890\" data-end=\"1922\"\u003eComplete ready-to-use system\u003c\/li\u003e\n\u003cli data-section-id=\"35eb5q\" data-start=\"1923\" data-end=\"1946\"\u003eReduces sample loss\u003c\/li\u003e\n\u003cli data-section-id=\"12mma45\" data-start=\"1947\" data-end=\"1973\"\u003ePrevents contamination\u003c\/li\u003e\n\u003cli data-section-id=\"1v3398c\" data-start=\"1974\" data-end=\"2019\"\u003eSuitable for sensitive biological samples\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2021\" data-end=\"2097\"\u003eThese features make it perfect for \u003cstrong data-start=\"2056\" data-end=\"2096\"\u003ebiotech and pharmaceutical workflows\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-section-id=\"7zpkrf\" data-start=\"2104\" data-end=\"2133\"\u003e\u003cstrong\u003eMaterial and Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2135\" data-end=\"2244\"\u003eVacufil units are made from \u003cstrong data-start=\"2163\" data-end=\"2206\"\u003ehigh-quality laboratory-grade materials\u003c\/strong\u003e, ensuring durability and performance:\u003c\/p\u003e\n\u003cul data-start=\"2246\" data-end=\"2354\"\u003e\n\u003cli data-section-id=\"138x8va\" data-start=\"2246\" data-end=\"2286\"\u003e\n\u003cstrong data-start=\"2248\" data-end=\"2261\"\u003eMembrane:\u003c\/strong\u003e Polyethersulfone (PES)\u003c\/li\u003e\n\u003cli data-section-id=\"gmwo4f\" data-start=\"2287\" data-end=\"2317\"\u003e\n\u003cstrong data-start=\"2289\" data-end=\"2301\"\u003eHousing:\u003c\/strong\u003e Polypropylene\u003c\/li\u003e\n\u003cli data-section-id=\"8kypr6\" data-start=\"2318\" data-end=\"2354\"\u003e\n\u003cstrong data-start=\"2320\" data-end=\"2340\"\u003eFunnel \u0026amp; Bottle:\u003c\/strong\u003e Polystyrene\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2356\" data-end=\"2443\"\u003eThis combination provides \u003cstrong data-start=\"2382\" data-end=\"2442\"\u003echemical resistance, strength, and sterile compatibility\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-section-id=\"17c5spd\" data-start=\"2450\" data-end=\"2471\"\u003e\u003cstrong\u003eWorking Principle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2473\" data-end=\"2529\"\u003eVacufil works on a \u003cstrong data-start=\"2492\" data-end=\"2528\"\u003evacuum-driven filtration process\u003c\/strong\u003e:\u003c\/p\u003e\n\u003col data-start=\"2531\" data-end=\"2732\"\u003e\n\u003cli data-section-id=\"12uep1o\" data-start=\"2531\" data-end=\"2581\"\u003eVacuum pressure is applied below the membrane\u003c\/li\u003e\n\u003cli data-section-id=\"1blojma\" data-start=\"2582\" data-end=\"2630\"\u003eLiquid is pulled through the filter rapidly\u003c\/li\u003e\n\u003cli data-section-id=\"1q3zclv\" data-start=\"2631\" data-end=\"2675\"\u003eContaminants and particles are retained\u003c\/li\u003e\n\u003cli data-section-id=\"hupgt0\" data-start=\"2676\" data-end=\"2732\"\u003eFiltered liquid is collected in the receiver bottle\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"2734\" data-end=\"2792\"\u003eThis ensures \u003cstrong data-start=\"2747\" data-end=\"2791\"\u003efast, efficient, and reliable filtration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-section-id=\"1iz91iu\" data-start=\"2799\" data-end=\"2815\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2817\" data-end=\"3058\"\u003e\n\u003cli data-section-id=\"1ma18x2\" data-start=\"2817\" data-end=\"2852\"\u003eComplete vacuum filtration unit\u003c\/li\u003e\n\u003cli data-section-id=\"vffdjz\" data-start=\"2853\" data-end=\"2899\"\u003e75mm PES membrane with low protein binding\u003c\/li\u003e\n\u003cli data-section-id=\"h34luf\" data-start=\"2900\" data-end=\"2933\"\u003eHigh flow rate and throughput\u003c\/li\u003e\n\u003cli data-section-id=\"8sye4n\" data-start=\"2934\" data-end=\"2980\"\u003eHydrophobic section to protect vacuum pump\u003c\/li\u003e\n\u003cli data-section-id=\"7edl7y\" data-start=\"2981\" data-end=\"3012\"\u003eReady-to-use sterile system\u003c\/li\u003e\n\u003cli data-section-id=\"1v3398c\" data-start=\"3013\" data-end=\"3058\"\u003eSuitable for sensitive biological samples\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-section-id=\"1xbduzz\" data-start=\"3065\" data-end=\"3094\"\u003e\u003cstrong\u003eBenefits of Using Vacufil\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3096\" data-end=\"3355\"\u003e\n\u003cli data-section-id=\"1psh1id\" data-start=\"3096\" data-end=\"3145\"\u003eMaintains protein integrity during filtration\u003c\/li\u003e\n\u003cli data-section-id=\"1msyyq6\" data-start=\"3146\" data-end=\"3187\"\u003eReduces filtration time significantly\u003c\/li\u003e\n\u003cli data-section-id=\"dbizmq\" data-start=\"3188\" data-end=\"3226\"\u003eEnsures contamination-free results\u003c\/li\u003e\n\u003cli data-section-id=\"1boowq6\" data-start=\"3227\" data-end=\"3271\"\u003eIdeal for large volume sample processing\u003c\/li\u003e\n\u003cli data-section-id=\"110uytx\" data-start=\"3272\" data-end=\"3306\"\u003eImproves laboratory efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"1ehdzg3\" data-start=\"3307\" data-end=\"3355\"\u003eProvides consistent and reproducible results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-section-id=\"1cgu054\" data-start=\"3362\" data-end=\"3389\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3391\" data-end=\"3966\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3391\" data-end=\"3474\"\u003e\n\u003ctr data-start=\"3391\" data-end=\"3474\"\u003e\n\u003cth data-start=\"3391\" data-end=\"3411\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"3393\" data-end=\"3405\"\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"3411\" data-end=\"3434\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"3413\" data-end=\"3426\"\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"3434\" data-end=\"3474\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"3436\" data-end=\"3447\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3557\" data-end=\"3966\"\u003e\n\u003ctr data-start=\"3557\" data-end=\"3638\"\u003e\n\u003ctd data-start=\"3557\" data-end=\"3576\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3559\" data-end=\"3575\"\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3576\" data-end=\"3598\" data-col-size=\"sm\"\u003eMembrane\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3598\" data-end=\"3638\"\u003ePolyethersulfone (PES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3639\" data-end=\"3720\"\u003e\n\u003ctd data-start=\"3639\" data-end=\"3658\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3658\" data-end=\"3680\" data-col-size=\"sm\"\u003eDiameter\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3680\" data-end=\"3720\"\u003e75mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3721\" data-end=\"3802\"\u003e\n\u003ctd data-start=\"3721\" data-end=\"3740\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3740\" data-end=\"3762\" data-col-size=\"sm\"\u003eHousing\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3762\" data-end=\"3802\"\u003ePolypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3803\" data-end=\"3884\"\u003e\n\u003ctd data-start=\"3803\" data-end=\"3822\" data-col-size=\"sm\"\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3822\" data-end=\"3844\" data-col-size=\"sm\"\u003eFunnel\/Bottle\u003c\/td\u003e\n\u003ctd data-start=\"3844\" data-end=\"3884\" data-col-size=\"sm\"\u003ePolystyrene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3885\" data-end=\"3966\"\u003e\n\u003ctd data-start=\"3885\" data-end=\"3904\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3887\" data-end=\"3902\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3904\" data-end=\"3926\" data-col-size=\"sm\"\u003eUse\u003c\/td\u003e\n\u003ctd data-start=\"3926\" data-end=\"3966\" data-col-size=\"sm\"\u003eProtein \u0026amp; Media Filtration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"5e5zvr\" data-start=\"3973\" data-end=\"3996\"\u003e\u003c\/h2\u003e\n\u003cp data-section-id=\"5e5zvr\" data-start=\"3973\" data-end=\"3996\"\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3998\" data-end=\"4446\" class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100.003%; height: 117.639px;\"\u003e\n\u003cthead data-start=\"3998\" data-end=\"4062\"\u003e\n\u003ctr data-start=\"3998\" data-end=\"4062\" style=\"height: 19.6065px;\"\u003e\n\u003cth data-start=\"3998\" data-end=\"4017\" data-col-size=\"sm\" class=\"\" style=\"width: 30.8131%; height: 19.6065px;\"\u003e\u003cstrong data-start=\"4000\" data-end=\"4012\"\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"4017\" data-end=\"4047\" data-col-size=\"sm\" class=\"\" style=\"width: 47.7787%; height: 19.6065px;\"\u003e\u003cstrong data-start=\"4019\" data-end=\"4029\"\u003eOption\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"4047\" data-end=\"4062\" data-col-size=\"sm\" class=\"\" style=\"width: 18.2163%; height: 19.6065px;\"\u003e\u003cstrong data-start=\"4049\" data-end=\"4060\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4127\" data-end=\"4446\"\u003e\n\u003ctr data-start=\"4127\" data-end=\"4190\" style=\"height: 19.6065px;\"\u003e\n\u003ctd data-start=\"4127\" data-end=\"4146\" data-col-size=\"sm\" style=\"width: 30.8131%; height: 19.6065px;\"\u003e\u003cstrong data-start=\"4129\" data-end=\"4145\"\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4146\" data-end=\"4175\" data-col-size=\"sm\" style=\"width: 47.7787%; height: 19.6065px;\"\u003eVacufil\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4175\" data-end=\"4190\" style=\"width: 18.2163%; height: 19.6065px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4191\" data-end=\"4254\" style=\"height: 19.6065px;\"\u003e\n\u003ctd data-start=\"4191\" data-end=\"4210\" data-col-size=\"sm\" style=\"width: 30.8131%; height: 19.6065px;\"\u003e\u003cstrong data-start=\"4193\" data-end=\"4201\"\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4210\" data-end=\"4239\" style=\"width: 47.7787%; height: 19.6065px;\"\u003eComplete Filtration Unit\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4239\" data-end=\"4254\" style=\"width: 18.2163%; height: 19.6065px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4255\" data-end=\"4318\" style=\"height: 19.6065px;\"\u003e\n\u003ctd data-start=\"4255\" data-end=\"4274\" data-col-size=\"sm\" style=\"width: 30.8131%; height: 19.6065px;\"\u003e\u003cstrong data-start=\"4257\" data-end=\"4269\"\u003eMembrane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4274\" data-end=\"4303\" data-col-size=\"sm\" style=\"width: 47.7787%; height: 19.6065px;\"\u003ePES\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4303\" data-end=\"4318\" style=\"width: 18.2163%; height: 19.6065px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4319\" data-end=\"4382\" style=\"height: 19.6065px;\"\u003e\n\u003ctd data-start=\"4319\" data-end=\"4338\" data-col-size=\"sm\" style=\"width: 30.8131%; height: 19.6065px;\"\u003e\u003cstrong data-start=\"4321\" data-end=\"4334\"\u003eSterility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4338\" data-end=\"4367\" data-col-size=\"sm\" style=\"width: 47.7787%; height: 19.6065px;\"\u003eSterile \/ Non Sterile\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4367\" data-end=\"4382\" style=\"width: 18.2163%; height: 19.6065px;\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4383\" data-end=\"4446\" style=\"height: 19.6065px;\"\u003e\n\u003ctd data-start=\"4383\" data-end=\"4402\" data-col-size=\"sm\" style=\"width: 30.8131%; height: 19.6065px;\"\u003e\u003cstrong data-start=\"4385\" data-end=\"4398\"\u003ePack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4402\" data-end=\"4431\" style=\"width: 47.7787%; height: 19.6065px;\"\u003ePack of 12\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4431\" data-end=\"4446\" style=\"width: 18.2163%; height: 19.6065px;\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Scilab EX","offers":[{"title":"Default Title","offer_id":41082591084616,"sku":null,"price":550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1688\/0968\/files\/CompleteVacuumFiltrationUnit.jpg?v=1776150081","url":"https:\/\/www.scilabex.com\/products\/vacufil-complete-vacuum-filtration-unit","provider":"Scilab EX","version":"1.0","type":"link"}